Fixing to the wall – HORIZONTAL version KORATHERM
Description
Flat panel radiators KORATHERM HORIZONTAL, KORATHERM HORIZONTAL - K, KORATHERM HORIZONTAL - M a KORATHERM HORIZONTAL VKM has got upper, lower and in some cases also central hangers welded at the back of the radiator, in case of length L = 1800 mm and longer they have got six hangers.
Position of hangers and table with sizes
KORATHERM HORIZONTAL, KORATHERM HORIZONTAL-K, KORATHERM HORIZONTAL - M, KORATHERM HORIZONTAL VKM | |||||||
---|---|---|---|---|---|---|---|
H [mm] | L [mm] | 500 ÷ 1600 | 1800 | 2000 | 2300 | 2600 | 3000 |
144 | I | 50 | 50 | 50 | 50 | 50 | 50 |
J | 5 | 5 | 5 | 5 | 5 | 5 | |
S, T | 160 | 160 | 160 | 160 | 160 | 160 | |
Q | - | 900 | 1000 | 1150 | 1300 | 1500 | |
R | - | - | - | - | - | - | |
218 | I | 50 | 50 | 50 | 50 | 50 | 50 |
J | 25 | 25 | 25 | 25 | 25 | 25 | |
S, T | 160 | 160 | 160 | 160 | 160 | 160 | |
Q | - | 900 | 1000 | 1150 | 1300 | 1500 | |
R | - | - | - | - | - | - | |
366÷958 | I | 125 | 125 | 125 | 125 | 125 | 125 |
J | 25 | 25 | 25 | 25 | 25 | 25 | |
S, T | 160 | 160 | 160 | 160 | 160 | 160 | |
Q | - | 900 | 1000 | 1150 | 1300 | 1500 | |
R | - | 900* | 1000* | 1150* | 1300* | 1500* |
* For types 20, 21 a 22.
Positioning
Type | K10H / K10VM / K10H / K10R / K10RM | K11V / K11VM / K11H / K11HK / K11HM / K11HVKM | K20V / K20VM / K20H / K20HK / K20HM / K20R / K20RM / K20HVKM | K21H / K21HM / K21HK / K21HVKM | K22H / K22HK / K22HM / K22HVKM |
---|---|---|---|---|---|
X1 | 63 | 63 | 75 | 75 | 75 |
X2 | 101 | 101 | 112 | 112 | 155 |
Values X1 and X2 are dependent on the type of fixing bracket actually used.
Wall brackets
We recommend using the Drilled bracket 18/120 (order code Z-U144) for mounting on the wall.
In case of other types of brackets, e.g. Single wall bracket (code Z-U320) or Single angular bracket (code Z-U300) it is necessary to keep the recommended number of brackets stipulated in the KORATHERM brochure on page 34 or 35.
- The set includes two brackets and two supports
- Metal parts are galvanized
- Preferably for use on walls made from solid or perforated bricks or cellular concrete
- For drilling into walls, it is necessary to use a ø 18 mm drill bit
- Maximum vertical load is 1000 N at D = 50 mm
Type | Order number |
---|---|
Drilled bracket 18/120 | Z - U144 |
Single wall bracket (Z-U320)
- The set includes two brackets, two supports, 8 x 60 mm screws, and ø 10 mm expansion plugs
- Metal parts are galvanized
- For use in concrete construction and cellular concrete or solid brick construction
- For wall mounting at a distance of D = 40 mm from the wall
- Maximum vertical load for the bracket is 500 N
Type | Order number |
---|---|
Single wall bracket | Z-U320 |
Single wall bracket - angular (Z-U300)
- The set includes two brackets, two supports, 8 x 60 mm screws, and ø 10 mm expansion plugs
- Metal parts are galvanized
- For use in concrete construction and cellular concrete or solid brick construction
- For wall mounting at a distance of D = 54 mm or 36 mm from the wall
- Maximum vertical load for the bracket is 700 N
Type | Order number |
---|---|
Single wall bracket - angular |
Z-U300 |